Infant incubator

MD, Gyne

Product information:‎
Brief introduction: microprocessor based servo controlled temperature system digital ‎display to indicate simultaneously , baby temperature air temperature .‎
The compartment body is made of the cold steel. ‎
The compartment body is made of high quality transparent acrylic , which is used in ‎medical purpose , as well as it , is anti friction .‎
The mattress has a mechanism .(lcd) monitor to display ‎
temperature , Alarms and set point .‎
A sensor for air temperature and another one for infant temperature . Digital display of ‎temperature .‎
Specification :
Power ‎
Model : am 3000………220/230vac, 50Hz / 60 Hz
‏ ‏Power input …… Alarm ‎
Power alarm ‎
Power failure … activates if primary power to the incubator fails or the power ‎wire is accidentally Disconnected from the wall receptacle ‎
FAN ALARM ‎
Fan failure .. activates if fan motor malfunctions
SENSOR ALARM
Air Sensor failure …. Air sensor malfunction , refer unit to service skin sensor ‎failure …. Activated when skin sensor malfunctions ‎
DEVIATION ALARM
High air temperature …activated if displayed air temperature is 1.5 c above set point . ‎
low air temperature ….. activated if displayed air temperature is 2.5 c below set point .‎
High skin temperature …… activated if displayed skin temperature 1.0 c above set point . ‎
Low skin temperature…… activated if displayed skin temperature 1.0 c below set point .‎
Over temperature alarm ‎
Over air temperature …. activated when displayed
‎ Over skin
Air temperatur…..20 c – 38 c for set temperature < 37 c , 38 c -39 c for set temperature 38 c ‎
Temperature activated when displayed skin temperature was approach38c for set temperature 37 c in skin mode ‎
Temperature control range and correl ative specifications
‎ skin temperature …20c – 37 c for set temperature 37 c ‎
temperature raise time ……. temperature variability ……….+0.5 c ‎
skin sensor precision …….. Environment Temperature ‎
Operation Temperature range …..+22c – 30 c ‎
Store temperature range -40 – + 55 c ‎
Environment humidity ‎
Operation humidity ‎
Range……….30% – 75% ‎
Store humidity
Range ……….10% – 100% ‎
Atmospheric pressure range 700 h pa ‎
Noise level within hood environment ‎
‎55db(environment noise below 45db)‎
Carbon dioxide (co2) in air delivered at 750 ml/min at appoint 10 cm above the center of the ‎mattress
Air velocity over mattress less than 0.35/s
Infant bed max load 10 kg
Transfusion shelf max load 2kg cabinet max load

All Our Products

Take a look at our products and contact us in any time to order it.

Anesthesia Machine

MD, EENT

Read More

Phototherapy

MD, EENT

Read More

Infant warmer

MD, EENT

Read More

Infant incubator

MD, Gyne

Read More

Pepeline

MBBS, MD, EENT

Read More

Syringe pump

MD, EENT

Read More

Anesthesia Equipment

Read More

عربى